S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

State Water Heaters

Technical Training Department

Ashland City, Tennessee © 2004

31

STC-077

GAS PRESSURE CHECK

STEP 13: CHECK AND ADJUST SUPPLY GAS PRESSURE.
Attach manometer or gas pressure gauge to pressure tap on gas valve or use adapter to check
pressure ahead of valve as near as possible to valve. All appliances being served by this gas sup-
ply line should be operating.

STEP 14: CHECK AND ADJUST MANIFOLD GAS PRESSURE.

STEP 13

SUPPLY GAS PRESSURE TEST

IF...

THEN

supply gas pressure is not between 5.0 and 14” W.C.
natural gas or 11.0 and 14” W.C. propane

adjust supply gas pressure (Recommended supply
minimum is 7.0” W.C. for natural gas models)

proper supply gas pressure is present

continue to Step 14.

STEP 14

MANIFOLD GAS PRESSURE TEST

IF...

THEN

manifold gas pressure is not:
natural gas models
3.5” W.C. ± 0.3” – SUF 155 & 199
4.0” W.C. ± 0.3” – SUF 240
propane gas models
10.0” W.C. ± 0.3” – all propane gas models.

adjust manifold gas pressure to values given for model

and fuel type (within 0.3” W.C. tolerance)
if manifold gas pressure cannot be adjusted to
maintain values given (within 0.3” W.C. tolerance)
replace gas valve.

manifold gas pressure is within tolerances given above

ignition should occur.

SUF 150, 199

Propane

SUF 240 Natural

Gas Valve

SUF 150, 199

Natural

Gas Valve