Component information, Orifice table – State Industries Utra-Force STC-077 User Manual

Page 33

Advertising
background image

S U F S E R V I C E H A N D B O O K

C O M P O N E N T I N F O R M A T I O N

Technical Training Department

State Water Heaters

STC-077

32

Ashland City, Tennessee © 2004

COMPONENT INFORMATION

ORIFICE TABLE

* -4 and -5 stamped with “P” for Propane
N O T E : Hex head of main burner orifice is upstream end — gas flows out of tapered end.

FLAME SENSING ROD

PART NUMBER

FLAME SENSING CURRENT

COMMENTS

192478

0.7 Micro Amp (µ)

SUF 150, 199, & 240

HOT SURFACE IGNITOR (HSI)

PART NUMBER

VOLTAGE

AMP

OHMS COLD

COMMENTS

192638

120 VAC

1.0

50 – 300

SUF 150, 199, & 240

ORIFICE TABLE

SUF MODEL

MAIN BURNER

ORIFICE NO.

MAIN ORIFICE SIZE

INCHES

AIR ORIFICES

PT. NO.

AIR ORIFICE

SIZE — INCHES

150

192477-1

0.235

192450-1

0.875

199

192477-0

0.304

192450-0

1.031

240

192477-2

0.360

192450-2

1.196

150 Prop

192477-5

0.141”

192450-5*

0.872

199 Prop

192477-4

0.166”

192450-4*

1.150

Advertising