8 reassembling the cabinet, 4 troubleshooting, Table21 troubleshooting – Sun Microsystems STOREDGE FC-100 User Manual

Page 30: Reassembling the cabinet, Troubleshooting

Advertising
background image

2-8

Sun StorEdge FC-100 Hub Installation and Service Manual • September 1998

2.3.8

Reassembling the Cabinet

Follow the instructions in your system or expansion cabinet documentation. If
necessary, be sure to:

Replace or close the top front panel

Replace or close the rear panel

Push the antitilt bar back into the cabinet

2.4

Troubleshooting

If a GBIC is properly installed, the Device Active LED for the GBIC should be on
and the Bypass LED should be off.

If the Device Active LED for a GBIC is flashing, replace the GBIC.

If a GBIC is installed and the Device Active LED for the GBIC is off and the Bypass
LED is on, see

TABLE 2-1

.

TABLE 2-1

Troubleshooting

Possible Cause

Solution

Module not properly inserted

Remove and reinsert the GBIC.

Diminished or missing signal from node

Plug the optical cable from the other device
into a known good GBIC.

Bad hub port

Move the GBIC to a known good port on
the hub.

Faulty GBIC

Replace the GBIC.