Siemens Plant Central Clock TC100 User Manual

Page 55

Advertising
background image

Configuration Tool

7-5



©

Siemens AG 2010 All Rights Reserved

SICLOCK

®

TC100 Operating Instructions

Number

Unique, three-part parameter number, e.g. 000.005.00012

Parameter

Related values are grouped in a parameter.
Parameter lists are displayed with square brackets after the parameter name,
e.g. "Leap second[20]".

Entry

The individual values of a parameter are each defined as an entry in a
parameter.

Note
Entries can be individually edited but not individually read or written. The
complete parameter is always read or written with all its entries. If it is in a list,
the complete list is read or written.

Value

Numerical value or setting of the parameter entry

Write protection – the parameter cannot be edited

The current authorization level does not allow write access to this
parameter.

Master level

The current authorization level allows reading, editing and writing of the
parameter.

Master level without upload – operationally critical parameter

The current authorization level allows reading, editing and writing of the
parameter.
In order to change such parameters in the device, you have to select the
parameter explicitly and write it individually. See Reading / writing
parameters, setting to factory defaults
(Chapter 7.3.4).

Display parameters

Display parameters can only be read, and are typically actual values.
In order to update the display of actual values, activate automatic update

.

Parameter info

Information about the selected parameter
Information on the selected parameter / entry is displayed here.

Table 7-3

Possible operations and displays in the Parameter tab

Field / button

Meaning / instruction

Note

If the Configuration Tool is not authorized or is used with lower authorization
rights, not all the parameters will be displayed. This restriction concerns, e.g., set-
tings under "System“.

Furthermore, the access rights change with the authorization level.