Parameter assignment

9-7



©

Siemens AG 2010 All Rights Reserved

SICLOCK

®

TC100 Operating Instructions

9.2.2

SIMATIC mode

SIMATIC mode is supported at the Ethernet port by two protocols:

PCS7-compatible mode

S5-compatible mode

The setting is made with the parameter
/SIMATIC Mode/Ethernet 1 (0.15.01).

Mode

You set the send clock between 0 s, 1 s and 10 s with the parameter entry
/SIMATIC Mode/Ethernet 1/Mode (0.15.01).

Send condition

You define whether the signal is always output or only when synchronized with
the parameter entry /SIMATIC Mode/Ethernet 1/Send Condition (0.15.01).

Destination address

You define the send address of the SIMATIC mode with the parameter entry
/SIMATIC Mode/Ethernet 1/Destination Address (0.15.01). The broadcast
address FF:FF:FF:FF:FF:FF is typically set.