12 messages, Messages – Siemens Plant Central Clock TC100 User Manual

Page 94

Advertising
background image

12-9



©

Siemens AG 2010 All Rights Reserved

SICLOCK

®

TC100 Operating Instructions

Messages

12

The messages are classified under four different types of event:

System (capacity for approx. 1,500 entries)

Application (capacity for approx. 4,500 entries)

Information (capacity for approx. 21,500 entries)

Warning (capacity for approx. 3,000 entries)

Messages for which an outgoing event is triggered are termed persistent indica-
tions. Persistent indications are, e.g., alarms.

For further information, see Archive (Chapter 7.4).

Note

Each type of event is managed in its own buffer in the device. If a buffer is full, the
next message of this type overwrites the oldest message in the buffer.

The size of the information buffer is sufficient for approx. 45 days. This in an ave-
rage value based on experience. However, the message volume can vary accor-
ding to the operating conditions and plant configuration.

Table 12-1

Overview of messages, with event type and brief description

Recording a synchronization input

Information

The recording of a synchronization input is pending because a threshold value has
been exceeded.

The battery has been switched off

Application

A user has used the Configuration Tool to switch off the battery in readiness for
storage.
See also Battery (Chapter 9.3.6).

Battery has been switched on automatically

Application

After a minimum period of operation, the battery was switched on automatically.
See also Battery (Chapter 9.3.6).

Bootloader has been updated

System and
Information

The bootloader has been successfully installed.

Bootloader has NOT been updated

System and
Information

The bootloader could not be installed.