Siemens SPARC ENTERPRISE M8000 User Manual

Page 17

Advertising
background image

Information

about

Software

9

RTIF1-
070823-001

Using the XSCF Web, when you selected SSH
on the snapshot screen, the maximum number
of character input for Host, Directory, ID, and
Password doesn't correspond to the maximum
number of character input on the XSCF Shell.

To specify the value which exceeds the
maximum number of character input for the
XSCF Web, use XSCF Shell.

RTIF1-
070824-002

On the XSCF Web, when you select Domain
Mode Configuration to perform various
settings, the pop-up screen may not appear but
"Undefined" may be displayed on the screen.

Select Domain Mode Configuration one more
time and perform the settings. Or once
terminate the XSCF Web and then perform the
settings.

RTIF1-
070824-005

On the XSCF Web, when you changed the
Refresh Interval value of the Monitor Message
Frame, the invalid pop-up "Confirmation
Domain mode" may appear.

Ignore the pop-up and close the screen.

RTIF1-
070824-006

On the tab browser, to the same host, when
you perform multiple log-in with the user
accounts of different user privileges, the user
privilege of the last log-in user account will be
applied to those pages which you've already
logged in.

When you use the tab browser, do not perform
multiple log-in to the same host.

RTIF1-
070824-011

While using FireFox2, in the Configuration
policy setting on the Domain Configuration
screen, when you specify a domain which is in
operation, an error display pop-up appears.
When you click on the Back button on this
error display pop-up and click on the Cancel
button on the inquiry screen to re-display the
data, the system remains in the error message
screen.

From the Menu, select the Domain
Configuration page again.

RTIF1-
070904-001

CLIs should display "Permission denied" when
it is executed in Standby XSCF.

Only the following CLIs can be executed on
the Standby XSCF: snapshot(8),
switchscf

(8).

Do not attempt to run any other CLI on the
Standby. Such attempts will report various
errors.

RTIF1-
070904-004

The latest communication field in
showarchiving

(8) command is not updated

regularly.

Disabling and re-enabling archiving refreshes
the Latest communication field in
showarchiving

(8) output.

RTIF1-
070914-003

When the XSCF switching performed, there
may be "SCF: Board control error (DMA
timeout)" stored in the error log.

There is no workaround.
This message can be safely ignored.

TABLE 3

XCP Issues and Workarounds (Continued)

ID

Description

Workaround