On SPARC Enterprise M8000/M9000 servers,
busstat

(1M) command may cause rebooting

of domains.

This bug has been fixed in Solaris 10 5/08. For
Solaris 10 8/07 or earlier, this has been fixed in
patch 127127-11.

There is no workaround. Do not use
busstat

(1M) command.

Check for the availability of a patch for this
defect.

6588555

XSCF failover during DR operation to the
permanent memory might cause domain
panic.

Do not start an XSCF failover while a DR
operation is running. Wait for a DR operation
to finish before starting the failover. If you
start the failover first, wait for the failover to
finish before starting the DR operation.

6588650

On occasion, the system is unable to DR after
an XSCF failover or XSCF reboot.

There is no workaround.

6589546

prtdiag

(8) command does not show all I/O

devices of the following cards:
• XSEFC402AF Sun StorageTek Enterprise

Class 4Gb Dual-Port Fibre Channel PCI-E
HBA

• XSEFC401AF Sun StorageTek Enterprise

Class 4Gb Single-Port Fibre Channel PCI-E
HBA

This bug has been fixed in Solaris 10 5/08. 
For Solaris 10 8/07 or earlier, this has been
fixed in patch 127127-11.

[Workaround]
Use prtdiag -v for full output.

6589644

After added the system board by DR, when the
switching occurred on the redundant XSCF
Units, the domain console may hang up.

The console can be recovered by pressing
Ctrl-q

(the "Ctrl" key and the "q" key).

6592302

Unsuccessful DR operation leaves memory
partially configured.

Try deleteboard(8) again.

TABLE 4

Solaris OS Issues and Workarounds (Continued)

CR ID

Description

Workaround