SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008

Note –

Do not fail to execute the diagnosis of newly mounted CMU in the maintenance

menu of addfru(8) command.

10. Confirm that the mounted CPU module has been recognized by the server, and the

error indicator asterisk (*) is not displayed.

11. Confirm no abnormality occurred by using showlogs error -v and

showstatus

(8) commands.

If you encounter any hardware abnormality of the XSCF contact a service engineer.

12. Move the key position on the operator panel from Service to Locked.

13. Sets the following for the CMU.

Set up XSB.

Set up the domain

Set up the CPU operational mode of the domain.

For each setting, see the SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide
.

14. Use the setdomainmode(8) command, disable the autoboot function of the

domain.

For detail, see the SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF User’s
Guide
.

15. Power on the domains.

16. Confirm that the target domain has been correctly started.

17. Confirm no abnormality occurred by using showlogs error -v and

showstatus

(8) commands.

If you encounter any hardware abnormality of the XSCF contact a service engineer.

XSCF> showhardconf -M

XSCF> showlogs error -v

XSCF> showstatus

XSCF> poweron -d domain_id

XSCF> showlogs power

XSCF> showlogs error -v

XSCF> showstatus