Siemens SPARC ENTERPRISE M8000 User Manual

Page 24

Advertising
background image

16

SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008

6508432

Many correctable errors (CE) may occur, and
despite these are the correctable errors,
domain may panic.

This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.

[Workaround]
Set the following to /etc/system and then
reboot the domain:

set pcie:pcie_aer_ce_mask = 0x2001

6508434

The domain may panic when an additional
PCI-X card is installed or a PCI-X card is
replaced by using PCI hot plug.

This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.

[Workaround]
Do not insert a different type of PCI-X card on
the same PCI slot by using PCI hot plug.

6509337

s10s_u3 wanboot fails - The server returned
416: Requested Range Not Satisfiable.

This bug has been fixed in Solaris 10 8/07.

6510861

When Dual-Channel Ultra320 SCSI Card
(SE0X7SC2F, SE0X7SC2X) is mounted,
correctable errors(CE) occur and system may
panic.

This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.

[Workaround]
Add the following entry to the /etc/system
file and then reboot the system:

set pcie:pcie_aer_ce_mask = 0x31c1

6511374

Unexpected error messages may be displayed
on console after changing the system
configuration.
Example:

WARNING: Translation error source

/LSB0/B0/0, PA 3c000000000, target

/LSB0/B0/20000000

This message can be safely ignored.

TABLE 4

Solaris OS Issues and Workarounds (Continued)

CR ID

Description

Workaround

Advertising
This manual is related to the following products: