Single slot usb/serial cradle, Single slot usb/serial cradle -6 – Symbol Technologies MC70 User Manual

Page 134

Advertising
background image

6 - 6

MC70 User Guide

Single Slot USB/Serial Cradle

Table 6-3

Troubleshooting the Single Slot USB/Serial Cradle

Symptom

Possible Cause

Action

LEDs do not
light when EDA
or spare battery
is inserted.

Cradle is not receiving
power.

Ensure the power cable is connected securely to both the cradle and to
AC power.

EDA is not seated firmly
in the cradle.

Remove and re-insert the EDA into the cradle, ensuring it is firmly
seated.

Spare battery is not
seated firmly in the
cradle.

Remove and re-insert the spare battery into the charging slot, ensuring
it is firmly seated.

EDA battery is
not charging.

EDA was removed from
cradle or cradle was
unplugged from AC
power too soon.

Ensure cradle is receiving power. Ensure EDA is seated correctly.
Confirm main battery is charging under Start - Settings - System -
Power
. The standard capacity battery (1900 mAh) fully charges in less
than four hours. The extended capacity battery (3800 mAh) fully
charges in less than eight hours.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty
battery.

The EDA is not fully
seated in the cradle.

Remove and re-insert the EDA into the cradle, ensuring it is firmly
seated.

Ambient temperature of
the cradle is too warm.

Move the cradle to an area where the ambient temperature is between
0

o

C and 35

o

C.

Spare battery is
not charging.

Battery not fully seated
in charging slot.

Remove and re-insert the spare battery in the cradle, ensuring it is
firmly seated.

Battery inserted
incorrectly.

Re-insert the battery so the charging contacts on the battery align with
the contacts on the cradle.

Battery is faulty.

Verify that other batteries charge properly. If so, replace the faulty
battery.

Ambient temperature of
the cradle is too warm.

Move the cradle to an area where the ambient temperature is between
0

o

C and 35

o

C.

During data
communication,
no data
transmits, or
transmitted data
was incomplete.

EDA removed from
cradle during
communications.

Replace EDA in cradle and retransmit.

Incorrect cable
configuration.

See the system administrator.

Communication software
is not installed or
configured properly.

Perform setup as described in the MC70 Integrator Guide.

Advertising