SMC Networks Air Weigh AW5800 User Manual

Page 25

Advertising
background image

25

NOTE:

A/D refers to the analog-to-digital conversion of the

sensor reading.

If the reading is below 750, or there is no reading at all
follow these steps to exert a pre-load on the sensor:


a. Loosen the nut on the non-cable end of the sensor.

b. Insert a wedge (i.e. a flat-blade screwdriver) under

the non-cable end of the sensor until an appropriate
A/D reading is reached, for example:

Steer

– 1000 (±250)

c. Tighten nut on non-cable end of sensor to 25 ft-lbs. If

A/D readings are still within range, remove wedge
and check A/D readings. Proceed with Step 30.



If the reading is above 1250:

d. Loosen the nut on the non-cable end of the sensor.
e. DO NOT WEDGE the sensor, lightly press on the top

of the non-cable end to change A/D reading.

f. Tighten nut on non-cable end of sensor to 25 ft-lbs.

Check A/D readings; if they are below 750 repeat
Steps 31 a - c. If they are above 1250, repeat Steps
31 d - f. If within range proceed with Step 32.

If using the Deflection Sensor Test Device: Before
connecting the sensor to the sensor extension cable, check
A/D readings and adjust if necessary at this time according
to Step 37 (see page 27). Otherwise, proceed with next step
of installation.