Deflection Sensor Specifications

Operating Temperature Range:

-40 to 85 Degrees C

Compensated Operating Temperature Range:

-10 to 40 Degrees C

Storage Temperature Range:

-40 to 85 Degrees C

Rated capacity:

*40,000 lbs Full Scale

Input:

5 VDC +/- 10%

Output:

4.5 VDC +/- 5 % @ Rated Capacity

Output range:

** 1.0 to 4.5 VDC +/- 5%

Environmental:

Nickel Plated Steel / IP rating = 65

* Depends on application; maximum deflection is 0.150 inches at

rated capacity.

** No load = 1.0 VDC +/- 10% out. Full / maximum load = 4.5 VDC

+/- 10% out.