Appendix B – Maintenance

32

M

AINTENANCE

Replacing the Lamp

Turn off the projector and remove the power cord prior to replacing the lamp. Allow

the lamp to cool for at least 15 minutes prior to opening the lamp door. (Please see
"Turn Off" on page 13

Follow these instructions to replace the lamp.

1. Loosen the two screws on the lamp door (A).

2. Remove the three screws securing the lamp to the chassis (B).
3. Pull the lamp handle (C) to remove the lamp module (D).
4. Reverse the steps above to install the new lamp module.

After you have installed the lamp, reset the lamp usage time in the OSD menus.

1. Press Menu on the control panel or remote control.
2. Select Advanced.

3. In the Advanced submenu, select Lamp Timer Reset.

B

D

B

B

A

C

Select
Advanced

Select
Lamp
Timer
Reset