Command data chart, Rs-232, Commu – Silicon Optix 50HD User Manual

Page 64: Communication

Advertising
background image

Appendix E – RS-232 communication

55

RS-232

COMMU

-

RS-232

COMMUNICATION

Command data chart

RS232 Control

Function

Command

Title

Min

Value

Max

Value

Default

Value

Example

Notes

Input signals-Write

SIG

0

7

Component 1 YPbPr ==
SIG00

Component 1 RGB ==
SIG01

Component 2 YPbPr ==
SIG02

Component 1 RGB ==
SIG03

PC == SIG04

DVI == SIG 05

Composite == SIG06

S-Video == SIG07

Input Signals-Read

SIG

SIG??

Brightness-Write

BRI

0

99

50

Brightness 50 == BRI50

Brightness-Read

BRI

BRI??

Contrast-Write

CON

0

99

50

Contrast 50 == CON50

Contrast-Read

CON

CON??

Sharpness-Write

SHA

0

11

5

Sharpness 5 == SHA50

Sharpness-Read

SHA

SHA??

Color-Write

COL

0

99

62

Color 62 == COL62

Color-Read

COL

COL??

Tint-Write

TIN

0

99

62

Tint 62 == TIN62

Tint-Read

TIN

TIN??

Color Temp-Write

CTE

0

4

0

Color Temp 7800K ==
CTE00

Color Temp 5500K ==
CTE01

Color Temp 6500K ==
CTE02

Color Temp 9300K ==
CTE03

Color Temp User Mode ==
CTE04

Color Temp-Read

CTE

CTE

Color Temp User-
Write

CTU

0

99

0

Color Temp User 4000K ==
CTU00

Color Temp User 4100K ==
CTU01

Color Temp User 13900K
== CTU99

Advertising