SATO DR300 User Manual

Page 79

Advertising
background image

DR300 Operator Manual

77

Ready/Busy

This is the hardware flow control for the serial interface on the DR printers. By
raising/lowering the voltage level on Pin 20 of the RS232 port, the printer notifies the
host when it is ready to receive data. Pin 40 (RS) and Pin 20 (DR) are the important
signals on the printer for this method of flow control. The host must be capable of
supporting this flow control method for it to function properly. The selection of 1 item or
multi items print buffer can be set by DIP switch.

Data stream (ESC + “A” ~ ESC + “Z”) from host might not be fully received by printer
under the following conditions:

• Printer is in printing process during Single Job Buffer Mode.

• Printer is engaged with error condition.


1 : Cable connection

Host

Printer

FG

1 FG

RD

2 SD

SD

3 RD

CS

4 RS

RS

5 CS

ER

6 DR

SG

7 SG

DR

20 ER



2 : Input/Output signal explanation

Pin No. Signal

Name

Direction Content

1

F G

-

Frame ground

2

S D

Output

Data transmitted from printer to host

3

R D

Input

Data transmitted from host to printer

4

R S

Output

“Low” level when error occurs in printer

5

C S

Input

Always hold “High”

6

D R

Input

Always hold “High”

7

S G

-

Signal ground

20

E R

Output

“High” when printer is ready to receive data
“Low” when various errors occur, when the printer is
offline, and while printing in the Single Job Buffer
Mode. It will also go “Low” when the data in the
buffer reaches the Buffer Near Fall Level


Chapter 10 - Serial Interface

Advertising