Fireplace framing specifications, Product reference information, Specifications – Superior MILLIVOLT SDVST-N-B User Manual

Page 11: Efficiencies, Steady state, Afue

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

11

NOTES

Annual Fuel Utilization Efficiency

Diagrams, illustrations and photographs are

not to scale – consult installation instruc-

tions. Product designs, materials, dimen-

sions, specifications, colors and prices are

subject to change or discontinuance without

notice.
Appliance has a factory-installed vent seal cap

(see Figures 14 and 15 on Page 13) in each

flue outlet.

Figure 12

FIREPLACE SPECIFICATIONS - MODEL SDVPF (PENINSULA VIEW)

Fireplace Framing Specifications

12 (305)

10

(254)

40-1/8

(1019)

3-1/2(89)

(16)

FRAMING SPACERS

(Top and Side)

FINISH WALL BRACKET

(Front, back, and left edge of unit top)

6-7/8

(175)

10-1/4

(260)

12

(305)

(63.5)

3 (76)

(13)

1/2

1/2

5/8

DETAIL OF

FINISH WALL BRACKET

FLUE

(Top or Side)

2-1/2

24

(610)

41

(1041)

37

(940)

43-5/8

(1108)

(13)

4 (102)

GAS INLET

ELECTRICAL

INLETS

2-1/2

(63.5)

FLUE

(Top or Side)

(873)

34-3/8

(610)

24

(610)

24

(464)

18-1/4

*41-1/2

(1054)

43-5/8

(1108)

(679)

11-3/8

(267)

7

(178)

5-1/8

(130)

12-1/8

(308)

10-1/2

22-3/4

(578)

inches (millimeters)

Gas Line

Center of gas line

is 3 in. (76 mm)

up from floor.

6-1/4

(159)

A

Minimum Framing

Stud Size is 2 x 4

7

(178)

12-1/8

(308)

5-1/8

(130)

Dimension A

Secure Vent - 46-1/2 (1181)

Secure Flex - 48-1/4 (1226)

26-3/4

PRODUCT REFERENCE INFORMATION

Cat.

No.

Model

Ship

Wt.

Ship.

Volume

H4634

SDVPF

270 lbs 52W x 27D x 44-

1/2H (36.2 cu.ft).

SPECIFICATIONS

Natural & Propane

Gas BTU Input

37,500

(MV Low 30,000)

Co-axial DV Vent Size

4-1/2" Inner

7-1/2" Outer

EFFICIENCIES

SDVPF

58 % (NG)

61 % (LP)

Steady State

72 % (NG)

73 % (LP)

• AFUE

68 % (NG)

68 % (LP)

Louvered Control

Compartment Door

Left Side View

Top View

u

This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing

spacers. (The 41-1/2 in. dimension permits easier fireplace installation, if unit is installed after framing is erected).

v

This dimension based on 5/8" drywall. For 1/2" drywall use 25-1/2" (648 mm). The finished dimension should be 26-1/2" (673 mm).

See also, Side Vent Seal Cap note below.

• Inches (millimeters)

• Minimum Framing Stud Size is 2 x 4

• See right side viewsof fireplace below for gas line inlet location options.

Gas Line Center of gas line is 3 in. (76 mm) up from floor.

Vertical Venting Through the Ceiling:

Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening,

10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 18 on Page 15).

Right Side View

Front View

Stepped to Accept Drywall on 2 Corners

Vent Framing - Top Vent

With One 90º Elbow

Vent Framing - Rear Vent

With No Elbows

Provide

additional

space for Side

Vent Seal Cap

if installing

against a solid

wall.

**25-1/4

(641)

10-1/2

(267)

12-1/8

(308)

5-1/8

(130)

12-1/8

(308)

26-3/4

(648)

5-1/8

(130)

Vent Center - Top

Vent with one 90

degree elbow

Vent Center- Side

Vent (no elbows)

A

v

u

Dimension A

Secure Vent 47 (1194)

Secure Flex 48-3/4 (1238)

Advertising