Step 5.

WIRING - OPTIONAL FORCED AIR

BLOWER

(FBK-100) (See Figure 45) -

An optional ON/Off (FRS) control switch is also

available (installs on bracket below valve). An

electrical outlet box is factory installed for the

connection of the electrical power supply to

the blower.

1. Route a 3-wire, 120Vac 60Hz 1ph power

line to the lower right rear corner of the

appliance.

2. Connect the black supply wire to the top

outlet's black pigtail lead and to the switch's

black lead. Connect the white supply wire to

the neutral terminal of the outlet box.

CAUTIONS

Remove the carton support from

the control compartment before

operating the appliance.

Ensure that wires are positioned

away from hot surfaces and sharp

edges.

Do not connect the optional wall

switch to a 120 Volt AC power

supply.

See Figure 45. It is not necessary to remove

the outlet box.

3. Connect the ground supply wire to the outlet

box green ground screw as shown.

4. Plug the blower cord into the bottom recep-

tacle of the outlet box.