Figure 18

Roof

Framing

Ceiling

Framing

Plumb

Bob

10-1/2" Min.

(267 mm)

10-1/2" Min.

(267 mm)

Figure 19

Align the dimple (four places) of the

upper vent section with the opening

of the locking incline channel on the

lower vent section or appliance col-

lar. Twist vent component clockwise

to engage and seal until arrow and

dimple align.

Dimple

Locking Incline

Channel

Connected Vent

Sections

Arrow

Arrow

Appliance Collar or

Vent Section

Vertical (Offset) Installation
Analyze the vent routing and determine the

number of vent sections and elbows required.

Refer to Vertical Vent Figures and Tables on

Pages 18 and 19 to select the type of vertical

installation desired. Vent sections are available

in net lengths of 4-1/2" (114 mm), 10-1/2" (267

mm), 22-1/2" (572 mm), 34-1/2" (876 mm) and

46-1/2" (1181 mm). Refer to the Vent Section

Length Charts on Page 14 for an aid in selecting

vent length combinations. Elbows are available

in 45° and 90° configurations. Refer to Figure

24 on Page 16 for the SV4.5E45 and SV4.5E90

elbow dimensional specifications.
Where required, a Telescopic Vent Section

(SV4.5LA) may be used to provide the installer

with an option in installing in tight and confined

spaces or where the vent run made up of fixed

length pieces develops a joint in a undesirable

location, or will not build up to the required

length. The SV4.5LA Telescopic Vent Section

has an effective length of from 1-1/2" (38 mm)

to 7-1/2" (191 mm). The SV4.5LA is fitted with

a locking inclined channel end (identical to a

normal vent section component) and a plain end

with 3 pilot holes. Slip the plain end over the

locking channel end of a standard SV4.5 vent

component the required distance and secure

with three screws.
Maintain a minimum 1" (25 mm) clearance

to combustible materials for all vertical ele-

ments. Clearances for all horizontal elements

are 3" (76 mm) on top, 1" (25 mm) on sides

and 1" (25 mm) on the bottom.
A.
Frame ceiling opening - Use a plumb line

from the ceiling above the appliance to locate

center of the vertical run. Cut and/or frame

an opening, 10-1/2" x 10-1/2" (267 mm x 267

mm) inside dimensions, about this center mark

(Figure 18).

14" Min.

Outer Pipe Of

Chimney

Use correct firestop

thimble depending on the

pitch of the interior

ceiling.

Note: Regular Thimble

(SV-FSTFE) Can Be Used

If A Header Is Constructed

At This Point

Figure 20

Push the vent component against the previous

section until it fully engages, then twist the

component clockwise running the dimples down

and along the incline channels until they seat at

the end of the channels. This seating position

is indicated by the alignment of the arrow and

dimple as shown in Figure 19.

D1. Install firestop/spacer at ceiling between

stories - Install a firestop/spacer (catalog

no. H2247 - Secure Vent; catalog no. H2249

- Secure Flex) at the bottom side of the ceiling

to the ceiling joists. Route the vent sections

through the framed opening and secure the

firestop/spacer with appropriate fasteners at

each corner.

Remember to maintain 1" (25 mm) clear-

ance between vertical chimney sections and

combustibles, framing members, and attic

or ceiling insulation.

D2. Install firestop thimble at the ceiling to

roof location - Position appropriate firestop

thimble (see Table on Page 36) at the bottom

side of ceiling and secure temporarily with

two appropriate fasteners. Attach permanently,

using at least two more fasteners, after vent sec-

tions have been assembled through the firestop

thimble and after any necessary adjustments

have been made.

Ensure the thimble penetrates the roof opening.

The thimble must extend completely through the

ceiling or roof cavity to the outermost plane of

the roof. Use thimble extension SVTE26 when

the distance between the outside of the roof and

the inside of the ceiling exceeds the height of

the firestop thimble. The thimble provides for

zero clearances to combustibles and must be

used at the ceiling/roof in manufactured homes

with Secure Vent double wall vent sections.

Maintain 1 in. (25.4 mm) clearance between

the thimble and the outer pipe of the secure

vent chimney system. See Figure 21 (Page

16) for pitched roofs or flat roofs with flat

ceilings or Figure 20 for pitched roofs with

cathedral ceilings.

To attach a vent component to the appliance

collar, align the dimpled end over the collar,

adjusting the radial alignment until the four lock-

ing dimples are aligned with the inlet of the four

inclined channels on the collar (refer to Figure

19). Push the vent component against the collar

until it fully engages, then twist the component

clockwise, running the dimples down and along

the incline channels until they seat at the end of

the channels. The unitized design of the Secure

Vent components will engage and seal both the

inner and outer pipe without the need for sealant

or screws. If desired a #6 x 1/2" screw may be

used at the joint, but it not required as the pipe

will securely lock when twisted.

Note: An elbow may also be attached to the

appliance collar. Attach in the same manner

as you would a vent section.

C. Attach vent components to each other

- Other vent sections may be added to the

previously installed section in accordance with

the requirements of the vertical vent Figures

and Tables. To add another vent component

to a length of vent run, align the dimpled end

over the inclined channel end of the previously

installed section, adjusting the radial alignment

until the four locking dimples are aligned with

the inlets of the four incline channels of the

previous section.

B. Attach vent components to appliance - Se-

cure Vent SV4.5 direct-vent system compo-

nents are unitized concentric pipe components

featuring positive twist lock connections (see

Figure 19).

All of the appliances covered in this document

are fitted with collars having locking inclined

channels. The dimpled end of the vent com-

ponents fit over the appliance collar to create

the positive twist lock connection.