DUCT

STATION

MINIMUM DIAMETER

DUCT

STATION

MINIMUM DIAMETER

*GAS

ELECTRIC

STEAM

*GAS

ELECTRIC

STEAM

A

9" (22.9 cm)

10" (25.4 cm)

G

23" (58.4 cm)

26" (66 cm)

B

12" (30.5 cm)

14" (35.6 cm)

H

25" (63.5 cm)

28" (71.1 cm)

C

15" (38.1 cm)

17" (43.2 cm)

I

26" (66 cm)

30" (76.2 cm)

D

17" (43.2 cm)

20" (50.8 cm)

J

27" (68.6 cm)

31" (78 cm)

E

19" (48.3 cm)

22" (55.9 cm)

K

29" (73.9 cm)

33" (83.8 cm)

F

21" (53.3 cm)

24" (61 cm)

L

30" (76.2 cm)

34" (86.4 cm)

T056IE3B

A

L

K

J

I

H

G

F

E

D

C

B

45˚

NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL
OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE
PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.

INSPECTION OR

CLEANOUT COVER

WALL

NO SCREEN

OR CAP

AIR OUT

2" (5.1 cm)

MINIMUM

T030IE3B

VERTICAL EXHAUST INSTALLATION

HORIZONTAL EXHAUST INSTALLATION

NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL
OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE
PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.

WALL

CONNECT TO
TUMBLER

2" (5.1 cm)
MINIMUM

CONNECT TO
TUMBLER

EXHAUST AIR FLOW

MAXIMUM LENGTH OF

DUCT 14 FEET

(4.3 m)

WALL

EXHAUST

OUTLET

NO SCREEN

OR CAP

2" (5.1 cm)
MINIMUM