DRYING TUMBLER ENCLOSURE CONSTRUCTION

IMPORTANT: DO NOT block airflow at top rear of
tumbler with laundry, etc. Doing so would prevent
adequate air supply to tumbler’s heat chamber.

A typical tumbler enclosure is shown in

Figure 23.

Note that enclosure does touch tumbler top and side
panels. Note, too, minimum and maximum
dimensions. Be aware that there may be local codes
and ordinances which must be complied with.

0" CLEARANCE

NOTE: Shaded areas
indicate adjacent structure.

0" CLEARANCE

PERMITTED FOR

FIRST 4" (10.16 cm)

4" (10.16 cm)

MAXIMUM

12" (30.5 cm)

MINIMUM

CLEARANCE

GUARD

24" (61 cm)

MINIMUM

36" (91.4 cm)

RECOMMENDED

FOR

MAINTENANCE

PURPOSES

PROVISION

FOR

MAKE-UP

AIR

T038IE3B

NOTICE:

CLEARANCE OF TUMBLER CABINET FROM COMBUSTIBLE

CONSTRUCTION MUST BE A MINIMUM OF 12 INCHES (30.5 cm) AT TOP.

To reduce the risk of serious injury,
install lockable doors to prevent public
access to rear of tumblers.

WARNING

IMPORTANT: Install tumblers with sufficient
clearance for servicing and operating, see
Figure 23.