ELECTRICAL REQUIREMENTS
For 75 Pound (34 kg) Tumblers

REQUIREMENTS

Figure 15

Heat Source

Electrical Specs

Wires Required and Terminal Block Connection

Gas & Steam

230/50/1

L1

L2

Ground to PE Busbar

Electric

208-230/50-60/3

L1

L2

L3

Ground to PE Busbar

Electric

380/50/3

L1

L2

L3

Ground to PE Busbar

Electric

415/50/3

L1

L2

L3

Ground to PE Busbar

Steam

380/50/3

L1

L2

L3

Ground to PE Busbar

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

ELECTRIC DRYING TUMBLERS

NOTE: DO NOT use aluminum wire.

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

208V / 240 V

1 Phase, 50 Hz.

208 / 240 V

3 Phase, 50 Hz.

380 / 415 V

3 Phase, 50 Hz.

Minimum Wire Size

14 AWG (2.081 mm²)

14 AWG (2.081 mm²)

14 AWG (2.081 mm²)

Circuit Breaker

15 AMP

15 AMP

15 AMP

Poles

2

3

3

Figure 16

Figure 17

ELECTRIC DRYING TUMBLERS

380 V, 3 Ph, 50 Hz.

415 V, 3 Ph, 50 Hz.

Minimum Wire Size

6 AWG (13.32 mm²)

6 AWG (13.32 mm²)

AMP Rating

48 Amp

45 Amp

Circuit Breaker

50 Amp

50 Amp

Poles

3

3

GROUNDING INSTRUCTIONS

Drying tumbler must be grounded. In event of malfunction or breakdown. Grounding will reduce risk of electric
shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a
grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit
conductors and connected to PE Busbar.

aWARNING

To reduce the risk of fire and electric shock, check with a qualified service technician
for proper ground procedures. Improper connection of the equipment grounding
conductor may result in risk of electric shock.

WARNING

To reduce the risk of fire and electric shock, if electrical supply is coming from a
three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.