Speed Queen Drying Tumblers SCB50EG User Manual

Page 53

Advertising
background image

51

M412616

PRELIMINARY OPERATING CHECKS

FINAL OPERATING CHECKS

Manual Dual Timer Tumbler

1. Set temperature selector to HIGH and set drying

and cool down selectors to their maximum
settings.

2. Press and hold in Push-to-Start Button for

approximately three (3) seconds. Motor will start,
heat system will turn on, drying indicator will light
and drying selector will rotate counterclockwise.

3. When drying selector reaches zero (0) heat

system will shut off, drying indicator will turn off,
cooling indicator will light and cooling selector will
rotate counterclockwise.

4. When cooling selector reaches zero (0) motor will

stop and cooling indicator will turn off indicating
drying cycle is finished.

Coin Operated Tumbler

1. Set temperature selector to HIGH.

2. Insert required amount of coins.

3. Press and hold in Push-to-Start Button for

approximately three (3) seconds. Motor will start
and heat system will turn on.

4. Near end of cycle a preset 2 1/2 minute cool down

cycle will start.

5. When metered time expires, motor will stop

indicating drying cycle is finished.

Electronic Control Tumbler

Tumbler comes equipped with Electronic Control.
Electronic Control gives owner a variety of
programming options. To learn how to use Electronic
Control, consult supplemental manual.

1. Remove or open all panels and inspect accessible

bolts, nuts, screws, terminals and fittings for
security.

2. Check belt tension, adjust if necessary (refer to

Adjustment Section).

3. Energize electrical circuit to tumbler circuit

breaker and turn on tumbler disconnect switch.

4. Turn on gas supply at manual gas shut off valve in

gas supply line (gas models only). Handle of gas
shut off valve should be parallel with gas supply
line when in “ON” position.

5. Press and hold in Push-to-Start Button for

approximately three (3) seconds. Release button
and open cylinder door. Cylinder should stop
rotating within seven (7) seconds after door is
opened 3" (7.5 cm) plus or minus 1/4" (0.635 cm).
If cylinder does not stop rotating, adjust cylinder
door interlock (refer to Adjustment Section).

6. Load tumbler with clothes or clean rags.

7. Start tumbler and check burner flame, adjust gas

inlet shutter if necessary (refer to Adjustment
Section).

8. Check air flow switch operation by opening lint

panel. Heating system should shut off when
lint panel is opened approximately 1-1/2"
(3.81 cm). Adjust if necessary (refer to
Adjustment Section).

9. Turn off tumbler.

10. Check air flow switch operation by opening lint

panel. Heating systems should shut off when lint
panel is opened approximately 6" (15.24 cm) with
a full load.