50 Pound (22 kg) Tumblers

LOW PRESSURE STEAM DRYING TUMBLERS

GROUNDING INSTRUCTIONS

Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric
shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a
grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit
conductors and connected to the PE Busbar.

WARNING

To reduce the risk of fire and electric shock, check with a qualified service technician
for proper grounding procedures. Improper connection of the equipment grounding
conductor can result in a risk of electric shock.

WARNING

To reduce the risk of fire and electric shock, if electrical supply is coming from a three
phase service, DO NOT connect a “Stinger Leg” to a single phase machine.

Figure 14

LOW PRESSURE STEAM DRYING TUMBLERS

240 V

1 Phase, 50 Hz.

Minimum Wire Size

14 AWG (2.081 mm²)

Circuit Breaker

15 AMP

Poles

2