Daily, Monthly – Speed Queen Drying Tumblers SCB50EG User Manual

Page 59

Advertising
background image

57

M412616

SECTION IV

Preventive Maintenance Instructions

DAILY

1. Make certain drying cycle has ended.

2. Open loading door.

3. Unlock and remove lint panel.

4. Remove accumulated lint in lint compartment.

Lint left in lint compartment will be drawn back
onto lint screen and restrict air circulation.

5. Clean lint from lint screen. If lint screen is torn

replace immediately. A torn lint screen allows lint
to flow into ductwork system restricting air
circulation.

6. Ensure lint screen covers entire opening in lint

screen hood. Gaps between lint screen and lint
screen hood allows lint to flow into ductwork
system restricting air circulation.

7. Wipe any accumulated lint off thermostat

sensing probe. Lint buildup on sensing probe will
cause overheating of tumbler.

8. Replace and securely lock lint panel.

Figure 34

WARNING

T046IE3A

THERMOSTAT

SENSING PROBE

LINT

SCREEN

MONTHLY

1. Perform daily cleaning of accumulated lint.

2. Deactivate electrical circuit by turning off electrical

disconnect switch on rear of tumbler.

4. Remove exhaust duct from rear of tumbler and

clean out all accumulated lint.

5. Reinstall exhaust duct.

6. Remove bottom cover from vertical exhaust duct

and clean out all accumulated lint.

7. Reinstall vertical exhaust duct cover.

8. Inspect entire duct work assembly and clean out

all accumulated lint.

9. Energize electrical circuit to tumbler by turning on

electrical disconnect switch on rear of tumbler.