LOW STEAM DRYING TUMBLERS

GROUNDING INSTRUCTIONS

Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric
shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a
grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit
conductors and connected to PE Busbar.

To reduce the risk of fire and electric shock, check with a qualified serviceman for
proper grounding procedures. Improper connection of the equipment grounding
conductor may result in a risk of electric shock.

WARNING

To reduce the risk of fire and electric shock, if electrical supply is coming from a three
phase service, DO NOT connect a “Stinger Leg” to a single phase machine.

WARNING

LOW PRESSURE STEAM DRYING TUMBLERS

240 V, 1 Phase 50 Hz.

Minimum Wire Size

16 AWG (1.309 mm²)

Circuit Breaker

20 AMP

Poles

2