Chapter 7 error messages, Powerup error messages – Socket Mobile GFK0121E User Manual

Page 59

Advertising
background image

7

7-1

GFK-0121E

Chapter

7

Error Messages

This chapter explains error messages that may be displayed on the Hand-held Monitor.

Powerup Error Messages

If an error occurs during the Hand-held Monitor’s
self-test, this multi-language error display may
appear:

P W R U P E R R O R # 1

E R R E U R # 1

E I G T E S T : F E H L # 1

E R R O R E I N I Z # 1

Cycle power to the Hand-held Monitor and try
again. If the message returns, look for its error
number in the list at right.

#2

The HHM has a faulty EPROM. Obtain a
replacement or an HHM upgrade kit.

#4

The HHM may have been assigned a De-
vice Number already used on the bus. Press
the ON/OFF key, then disconnect the HHM
from the device it is attached to. Press the
ON/OFF key again. Following the instruc-
tions on page 3-4, assign the HHM a differ-
ent Device Number.
At 38.4 Kbaud, unterminated HHM cable
may cause this message. Remove the HHM
cable or check that HHM is connected to a
properly-terminated bus.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.

#5

This number indicates an internal fault, or
excessive noise on the bus, or that the bus is
operating at a different baud rate from the
HHM. Press the ON/OFF key then discon-
nect the HHM cable from the bus

and from

the HHM. Press the ON/OFF key again. If
the message reappears, replace the HHM.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.

#1, 2, 3,

or 6 indicates that the Hand-held Monitor

must be replaced.