Stinger JPEG 2000 User Manual

Page 24

Advertising
background image

Setup

4. Alarm Setup:
Set type of alarm sensors connected to DVR unit.
N.O represents Normal Open type and N.C Normal Close type.
1. ALARM INPUT: Select type of alarm sensor connected to DVR unit (N.O or N.C).

Use direction button and [-] [+] button to set.
DISABLE represents not to use alarm sensor connected to DVR.

2. DURATION: Set the duration of alarm when an ALARM is activated. (0 sec. ~ 300 sec.)

6. Buzzer Setup
Set parameters for buzzer (On or Off). Use direction button and [ENTER] button.

KEY BEEP: Buzz when button is pressed.
VIDEO LOSS: Buzz when video signal is lost.
ALARM ACTIVE: Buzz when alarm is activated.
MOTION DETECT: Buzz when motion is detected.

User can set all buzzers at On/Off at once by set ALL at ON/OFF.