Non-numeric error messages – Kodak RP 50 2J0686 User Manual

Page 116

Advertising
background image

Diagnostics and Troubleshooting

5-26

October 2002

Non-Numeric Error Messages

Error Message

Possible Cause/Subsystem

Possible Solution

An underrun error occurred during
communications to the following
device.

• The cable between the printer

and the host computer is worn.

• One or more of the connections

between the printer and the host
computer has malfunctioned.

• Check that all of the cables are

properly connected.

• Check the cables and

connections between the printer
and the host computer for wear
and if necessary, replace them.

An UNKNOWN error occurred
during communications to the
following device.

An unknown error occurred in the
application.

• Restart the calibration application.
• If the problem continues, make

sure you have the Calibration
Application and ASPI SCSI
device driver installed correctly.

Device not found.

The host computer attempted to
contact the printer at the specified
SCSI ID but did not get a response.

• Make sure that the printer is

turned on and is on-line.

• Make sure the Calibration

Application and ASPI SCSI
device driver are installed
correctly.

Invalid Device ID.

The host computer attempted to
contact the printer at the specified
SCSI ID but did not get a response.

Make sure that the printer is turned
on and is on-line

The following device is busy.

The printer at the specified SCSI ID
is busy.

Check that all of the cables are
properly connected.

The following device is closed.

The connection between the printer
and host computer was lost.

Check that all of the cables are
properly connected.

Advertising