System Operating Procedures

3-38

October 2002

Displaying the Min Max Development Time

NOTE: The fastest and slowest development times, as recorded from the last time

the screen was reset, can be seen from this screen.

1.

Select the Drive screen.

2. Press

Set three times to access the Drive screen in Calibrate mode.

3. Press

the

Down Arrow to reset the Min Max values.

4. Press

Set twice or a different blue function key to return to View mode.

Managing the Material Sensors

Material sensors are represented on the Material screen by solid or hollow circles.
There are four sensors at the feed end of the processor and one sensor at the exit
end of the processor. If a sensor detects material, its corresponding circle on the
material screen becomes solid. If no material is detected, the circle on the
material screen remains hollow. If there is material in the processor, shifting dots
are displayed at the bottom of the material screen, next to the circles that
represent the feed end sensors.

Viewing the Material

Press Material to access the Material screen.

Viewing the Processor Setup

1.

Press Material to select the Material screen.

2. Press

the

Up Arrow to select the Processor Setup screen.

NOTE: The processor is currently operating using the development time,

replenishment rate and dryer setting for setup A, KODAK Digital.

Selecting the Processor Setup

1.

Press Material to select the Material screen.

2. Press

the

Up Arrow to select the Processor Setup screen.

3. Press

Set to access the Setup screen in the Set mode.

4. Use

the

Up or Down Arrow to change the operating setup.

NOTE: Changing the setup resets the development time, replenishment rates

and dryer setting to the values in the selected setup. The calibrations
are not affected.

5. Press

Set or a blue function key to cancel the Set mode.