Monthly maintenance, Main drive chain, Checking the temperature of the solutions – Kodak RP 50 2J0686 User Manual

Page 85: Checking and adjusting the speed of the processor, Monthly maintenance -11

Advertising
background image

Maintaining the Equipment

October 2002

4-11

Monthly Maintenance

Main Drive Chain

WARNING:

Turn off the main power to the processor on the operator control
panel and at the circuit breaker to prevent injury from moving
parts and high voltage electricity and to prevent losing the
processor parameters.

Grease the main drive chain in the processor with lithium grease.

Checking the Temperature of the Solutions

After the warm-up period is complete, check that the temperatures of the solutions
in the processor are correct. If necessary, calibrate the temperature settings for
the solutions in the processor. See “Calibrating the Temperatures” on page 3-35.

Checking and Adjusting the Speed of the Processor

To determine if the processor is operating at the correct speed, run a cleanup
sheet through the processor while checking the elapsed time. If needed, adjust
the development time. See “Setting the Development Time Tolerance” on
page 3-41.



main

drive

chain

Advertising