Kohler COMMAND CH18-745 User Manual

Page 192

Advertising
background image

11.7

Section 11

Reassembly

11

Figure 11-19. Closure Plate Sealant Pattern.

4. Make sure the end of the governor cross shaft is

lying against the bottom of cylinder 1 inside the
crankcase. See Figure 11-13.

5. Install the closure plate to the crankcase.

Carefully seat the camshaft and the crankshaft
into their mating bearings. Rotate the crankshaft
slightly to help engage the oil pump and governor
gear meshes. See Figure 11-20.

Figure 11-22. Torquing Closure Plate Fasteners.

Install Stator and Backing Plates

1. Apply pipe sealant with Teflon

®

(Loctite

®

No 59241

or equivalent) to the stator mounting holes.

2. Position the stator aligning the mounting holes so

that the leads are at the bottom, towards the
crankcase.

3. Install and torque the two hex. flange screws to

6.2 N·m (55 in. lb.). See Figure 11-23.

3. Apply a 1.5 mm (1/16 in.) bead of sealant to the

sealing surface of the closure plate. See Figure
11-19 for sealant pattern.

Figure 11-20. Using Spanner Wrench to Turn
Crankshaft.

1

10

8

6

4

2

9

7

5

3

6. Install the ten hex. flange screws securing the

closure plate to the crankcase. Torque fasteners
in the sequence shown in Figure 11-21 to
24.4 N·m (216 in. lb.). On some engines one of
the ten mounting screws is plated. The plated
screw is typically installed in the #6 hole shown in
Figure 11-21.

Figure 11-21. Closure Plate Fastener Torque
Sequence.