11.22

Section 11
Reassembly

Figure 11-78. Adjusting Governor Lever.

4. Insert a nail into the hole on the cross shaft and

rotate the shaft counterclockwise as far as it will
turn, then torque the hex. nut to 6.8 N·m
(60 in. lb.)
. See Figure 11-79.

Figure 11-79. Holding and Tightening Governor Arm.

5. Reconnect the lead wire to the fuel shut-off

solenoid if so equipped.

Install Throttle & Choke Controls

1. Connect the choke linkage to the carburetor and

choke actuator lever. See Figure 11-80.

Figure 11-80. Connecting Choke Linkage.

2. Mount the main control bracket, and air cleaner

support bracket (if used) to the cylinder heads
using the four hex. flange screws. Torque the
screws to 10.7 N·m (95 in. lb.) into new holes, or
7.3 N·m (65 in. lb.) into used holes. See Figure
11-81.

Figure 11-81. Torquing Main Control Bracket.

2. Make sure the throttle linkage is connected to the

governor lever and the throttle lever on the
carburetor.

3. Move the governor lever toward the carburetor

as far as it will go (wide-open throttle) and hold in
position. See Figure 11-78.

Advertising