11.19

Section 11

Reassembly

11

Figure 11-67. Breather Cover Fastener Torque
Sequence.

Reconnect Rectifier-Regulator

1. Install the rectifier-regulator in the blower housing,

if removed previously, then connect the rectifier-
regulator ground lead with the washer and silver
screw through the eyelet as shown in Figure
11-68. If a grounding bracket is used, secure with
the lower mounting screw and washer, against the
outer side of the rectifier-regulator. See Figure
11-70.

Figure 11-70. Grounding Bracket and Attached
Connector.

SMART-SPARK

Module

1. On engines with SMART-SPARK

, reinstall the

SAM module to the blower housing or cylinder
baffle. Do not over-tighten the retaining screws.
See Figure 11-71.

Figure 11-68. Connecting Ground Lead.

2. Install the B+ terminal/lead into the center position

of the rectifier-regulator plug and connect the plug
to the rectifier-regulator. See Figures 11-69 and
11-70.

1

2

3

4

Figure 11-69. Installing B+ Lead into Plug.

Grounding