Operation, Welding operation, Hand and foot amptrol – Lincoln Electric SQUARE WAVE TIG 255 SVM100-A User Manual

Page 21: Tig welding, Tig welding guidelines, Accessory operation

Advertising
background image

B-8

OPERATION

SQUARE WAVE TIG 255

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TABLE B.1

RECOMMENDED POLARITY SETTINGS FOR

TIG WELDING

Type of Welding

Electrode

Polarity

High Frequency

Setting

Stainless Steel

Aluminum & Magnesium

Other Metals

DC-

AC

DC-

START

CONTINUOUS

START

WELDING OPERATION

TIG WELDING

Familiarize yourself with the Controls and Display
Section before attempting operation of the Square
Wave TIG 255.

TIG WELDING GUIDELINES

TIG welding can be done in either the TIG 2-Step or
the TIG 4-Step Weld Mode. TIG 2-Step is typically
used with Hand or Foot Amptrols, with Remote
Current control. TIG 4-Step is typically used with Arc
Start switches and Local Current Control, because it
provides a very brief current upslope, and a 5-second
current downslope. TIG 4-Step also functions like a
trigger interlock, making it unnecessary to hold down
the Arc Start switch during a weld. Read the TIG
Welding Sequence of Operation sections for more
details on 2-Step and 4-Step Operation.

Refer to Table B.2 for guidelines on electrode sizes,
torch nozzles and shielding gas flow rates.

HAND AND FOOT AMPTROL

ACCESSORY OPERATION

Both the Hand and Foot Amptrol work in a similar
manner. They are meant to be used for remote current
control when Remote Current Control is selected.
The TIG 2-Step mode must be selected when using
an Amptrol for remote current control. As explained
below, Amptrols can also be used as arc start
switches if Local Current Control is selected.

For simplicity, the following explanation will refer only
to “Amptrols”, meaning both Foot and Hand models.
The term “minimum” refers to a Foot pedal in the “up”
position, as it would be with no foot pressure, or a
Hand Amptrol in the relaxed position, with no thumb
pressure. “Maximum” refers to a fully depressed Foot
Amptrol, or a fully extended Hand Amptrol.

The Amptrol is capable of controlling the output
current from 5 amps to the preset current displayed on
the ammeter. For example, if the ammeter is preset
for 200 amps and the Current Control switch is in the
REMOTE position, the Amptrol, when depressed just
past its minimum position, will cause the Square
Wave TIG 255 to weld at 5 amps. At the Amptrols
maximum position, the output would be near 200
amps.

It is important to note that, for many applications, the
tungsten will not start an arc at only 5 amps. To start
an arc reliably, it is important to depress the Amptrol
far enough so that the machine output current is near
the tungsten operating range. In the example above, a
3/32” tungsten may be used on DC- to weld near 200
amps. To start the weld, the operator may have to
depress the Amptrol approximately 1/4 of the way
down, or to nearly 50 amps, in order to start the arc.
Merely depressing the Amptrol to its 5 amp minimum
position will not start the arc.

If the Current Control switch is set to the LOCAL
position, an Amptrol can be used as an arc start
switch. Depressing the Amptrol just past minimum will
cause the Amptrols built-in arc start switch to close,
and backing off completely causes the built-in start
switch to open. The Amptrol will have no effect on the
welding current when used as an arc start switch.