Oscilloscope waveforms, Troubleshooting & repair, 50 volts 2ms ch1 – Lincoln Electric SQUARE WAVE TIG 255 SVM100-A User Manual

Page 72

Advertising
background image

SQUARE WAVE TIG 255

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-31

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

DC STICK MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

• Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

0 volts

50 volts

2ms

CH1

This is the typical DC (+) output voltage
waveform generated from a properly operat-
ing machine. Note that each vertical divi-
sion represents 50 volts and that each hori-
zontal division represents 2 milliseconds in
time.

Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.

Volts/Div................................50 V/Div.

Horizontal Sweep .................2 ms/Div.

Coupling .........................................DC

Trigger .....................................Internal

SCOPE SETTINGS

Advertising