F-36

TROUBLESHOOTING & REPAIR

0 volts

20 volts

2ms

CH1

AC TIG MODE (AUTO - BALANCE ON)

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

• Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

0 volts

20 volts

2ms

CH1

These are typical AC output voltage wave-
forms generated from a properly operating
machine. Note each vertical division repre-
sents 20 volts and each horizontal division
represents 2 milliseconds in time. The
machine was loaded with a resistance grid
bank. As the load is increased the output
waveform becomes more “square”.

Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.

MACHINE LOADED TO 50 AMPS AT 26VAC

MACHINE LOADED TO 200 AMPS AT 46 VAC

Volts/Div................................20 V/Div.

Horizontal Sweep .................2 ms/Div.

Coupling .........................................DC

Trigger .....................................Internal

SCOPE SETTINGS