F-44

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Should a machine under test be rejected for
any reason requiring the removal of any
mechanical part that could affect the
machine’s electrical characteristics, or if any
electrical components are repaired or
replaced, the machine must be retested.

NOTE: 50 Hz machines may be tested
using 60 Hz power.

Input Volts/Hertz

Maximum Idle Amps

208/60

44.0

230/60

40.0

200/50

47.0

220/50

43.0

380/50

25.0

Voltage Across

Power Factor

447-473 VAC

Capacitors

INPUT IDLE AMPS

TIG Modes

5 Amps @ 12 Volts

MAXIMUM ACCEPTABLE OUTPUT VOLTAGE –

AT MINIMUM OUTPUT SETTINGS

TIG Modes

255 Amps @ 29 Volts

MINIMUM ACCEPTABLE OUTPUT VOLTAGE –

AT MAXIMUM OUTPUT SETTINGS

OPEN CIRCUIT VOLTAGES

Stick Mode OCV

AC

69 – 73 VAC

DC

69 – 73 VDC

TIG Mode OCV

AC

46 – 54 VAC

DC

46 – 54 VDC

RECOMMENDED METERS FOR MACHINE OUTPUT TESTS

VOLTMETER:

AC and DC True RMS Meter – Fluke 8922A or equivalent

AMMETER:

Columbia Type AX AC or DC Tong Ammeter

IMPORTANT: IF OTHER TYPE METERS ARE USED RESULTS MAY NOT BE ACCURATE.