TROUBLESHOOTING & REPAIR

CONTROL TRANSFORMER (T2) VOLTAGE TEST

(continued)

CONTROL BOX

CONTROL BOARD LOCATED INSIDE
CONTROL TRANSFORMER LOCATED INSIDE

SUPORT CASE BACK
AND CENTER BAFFLE

WITH WOOD 2 X 4

TEST PROCEDURE

1.

Remove main supply power to machine

2.

Locate and remove Plug J8 from control
board, located in the control box. Hint:
For ease of testing, secure Plug J8 to
case front with tape.

3.

Locate leads #432 and #433 connected
to the control transformer (T2) which is
located in the top of the control box.

4.

Turn main power ON

FIGURE F.3 - LOCATION OF CONTROL BOARD AND CONTROL TRANSFORMER.

5.

Check for 120VAC at leads #432 to
#433

A.. If 120VAC is present at leads #432

to #433, go to Step 8.

Note: If main supply voltage varies,
control transformer voltages will
vary accordingly.

B.

If a very low or zero voltage is

shown at leads #432 to #433 then
go to Step 6.

6.

Remove main supply power to machine.