TROUBLESHOOTING & REPAIR

ARC START TRIGGER CIRCUIT TEST

TEST DESCRIPTION

The Arc Start Trigger Test determines if the wiring and connections are good from the
six pin amphenol receptacle to the protection/snubber board and also from the protec-
tion/snubber board to the control board.

MATERIALS NEEDED

Ohmmeter (Multimeter)
TIG 255 Wiring Diagrams (see Electrical Diagrams section of this manual)
Arc Start Trigger Circuit, (Figure F.10)

WARNING

CAUTION

Service and repair should only be performed by Lincoln Electric factory trained person-
nel. Unauthorized repairs performed on this equipment may result in danger to the
technician or machine operator and will invalidate your factory warranty. For your safe-
ty and to avoid electrical shock please observe all safety notes and precautions
detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform
the tests/repairs safely, contact the Lincoln Electric service department for technical
troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353
(WELD).

_____________________________________________________________________

If machine case sides and top are removed the case back and front must be support-
ed. Failure to do this could result in mechanical or electrical damage to the TIG 255.

_____________________________________________________________________