Troubleshooting & repair, Continued), Active scr test – Lincoln Electric SQUARE WAVE TIG 255 SVM100-A User Manual

Page 70

Advertising
background image

SQUARE WAVE TIG 255

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-29

TROUBLESHOOTING & REPAIR

ACTIVE SCR TEST

(continued)

PROTECTION/SNUBBER

L9255

J10

J11

J12

J13

J14

J15

REMOVE PLUGS J10 & J13

TEST PROCEDURE

1.

Remove main supply power to machine

2.

Remove plugs J10 and J13 from protec-
tion/snubber board. See Figure F.13.

3.

Remove red insulating paint from heat
sink test points. See Figure F.14. DO
NOT DISASSEMBLE THE HEAT
SINKS.

FIGURE F.13 - PROTECTION/SNUBBER BOARD PLUG LOCATIONS.

SCR1
ANODE

CATHODE
(1 & 2)

SCR2
ANODE

SCR3
CATHODE

SCR4
CATHODE

ANODE
(3 & 4)

PLUG
P10

FIGURE F.14 - SCR TEST POINTS.

4.

Perform test procedure as outlined in
Figure F.15. Repeat test for all four
SCR’s

5.

Replace any SCR assembly that does
not pass test in Step 4

Advertising