Troubleshooting & repair, 20 volts 2ms ch1 – Lincoln Electric SQUARE WAVE TIG 255 SVM100-A User Manual

Page 76

Advertising
background image

SQUARE WAVE TIG 255

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-35

TROUBLESHOOTING & REPAIR

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

DC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

• Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

0 volts

20 volts

2ms

CH1

This is a typical DC (+) output voltage wave-
form generated from a properly operating
machine. Note that each vertical division
represents 20 volts and that each horizontal
division represents 2 milliseconds in time.
The machine was loaded with a resistance
grid bank. The TIG 255 display read 200
amps at 50VDC.

Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.

MACHINE LOADED TO 200 AMPS AT 50 VDC

Volts/Div................................20 V/Div.

Horizontal Sweep .................2 ms/Div.

Coupling .........................................DC

Trigger .....................................Internal

SCOPE SETTINGS

Advertising