F-34

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

AC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

• Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

0 volts

50 volts

2ms

CH1

This is the typical AC output voltage wave-
form generated from a properly operating
machine. Note that each vertical division
represents 50 volts and that each horizontal
division represents 2 milliseconds in time.

Note: Scope probes connected at machine
output studs: (+) probe to electrode, (–)
probe to work.

Volts/Div................................50 V/Div.

Horizontal Sweep .................2 ms/Div.

Coupling .........................................DC

Trigger .....................................Internal