E-3

TROUBLESHOOTING

E-3

COMMANDER 500

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local

Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Engine will not idle down to low
speed.

Engine will not go to high idle when
attempting to weld.

Engine will not go to high idle when
using auxiliary power.

1. Idler switch in

High

idle position.

Set switch to

Auto.

2. External load on welder or auxil-

iary power. Remove all external
loads.

1. Poor work lead connection to

work. Make sure work clamp is
tightly connected to clean base
metal.

2.

Welding Terminals

switch is in

wrong position. Set to

Always

On

when welding without a weld-

ing terminal control cable. Refer
to Operations chapter for proper
use of this switch.

1. Auxiliary power load is less than

100 watts. Idler may not respond
with less than a 100 watt load.
Set Idler to

High

Contact your

Local Lincoln Authorized

Field Service Facility

for technical

troubleshooting assistance.