DIAGRAMS

F-6

COMMANDER 500

CONNECTION DIAGRAM:

CAUTION :

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPICATIONS. SEE OPERATING MANUAL.

75

32

31

41

42

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.D. SPLICE LEADS AND INSULATE.

THE ENGINE WELDER OPERATING MANUAL.

PLACE LOCAL / REMOTE SWITCH IN "REMOTE" POSITION.

GND

31

4

21

B

C

A

14 PIN

AMPHENOL

TO WORK

TO WORK

ELECTRODE

TO WIRE FEED UNIT

ELECTRODE CABLE

WIRE

FEEDER

K196

K867 UNIVERSAL

ADAPTER PLUG

INPUT CABLE

S23989

COMMANDER / K867 / LN-8 CONNECTION DIAGRAM

7-18-98

2

4

76

77

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".