Service and repair should be performed by only Lincoln Electric factory trained personnel.

Unauthorized repairs performed on this equipment may result in danger to the technician

or machine operator and will invalidate your factory warranty. For your safety and to avoid

electrical shock, please observe all safety notes and precautions detailed throughout this

manual.

If for any reason you do not understand the test procedures or are unable to perform the

test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-

bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

The following procedure will aid the technician in removing the output rectifier bridge for

maintenance or replacement.

MATERIALS NEEDED

Misc. Hand Tools

Dow Corning 340

Wiring Diagram

OUTPUT RECTIFIER BRIDGE REMOVAL

AND REPLACEMENT