Rack, Peration – Lindy Carbon Monoxide Alarm User Manual

Page 24

Advertising
background image

Rack

4.5.1

(SNMP CONFIGURATION)

Complete control of the RMS via
SNMP with alarm (trap function)
and support of separate
communities for read and write
operations.
SNMP V1 in accordance with RFC
1213 is implemented. MIB-II
including RMS private MIB is
supported.
The complete MIB file of the RMS
is on the supplied CD-ROM.
Explanation of the MIB variables
> A3.

Visualised integration in manage-
ment platforms on request.

[N] N

AME

Administrative name of the device.
For example: “RMS”

[L] L

OCATION

Description of the location of the
device.

[C] C

ONTACT

Name of the person responsible
for this device and contact infor-
mation. For example:
“LINDY support,
Tel. +49 (0) 621 / 47 005 - 0”

[R] R

EAD

C

OMMUNITY

Name of the community with the
right to read SNMP variables.
For example: “public”

[W] WRITE COMMUNITY
Name of the SNMP community
with the right to write SNMP
variables.
For example: “private”

[T] T

RAP

C

OMMUNITY

Name of the SNMP community
with the right to receive traps from
this device.
For example: “alarm”

O

PERATION

O

PERATION

[S] S

END

A

UTHTRAPS

Send trap with unauthorised
access with invalid or incorrect
Community String (authority trap)..

[M] SNMP A

CCESS

Enable or disable access via SNMP.
– Trap Destinations –
List of a maximum of 8 IP
addresses to which SNMP traps
are sent.

[A] A

DD

N

EW

T

RAP

D

ESTINATION

Add an IP address to the list of
trap receivers..

[D] D

ELETE

T

RAP

D

ESTINATION

Delete IP address from the list of
trap receivers.

[?] H

ELP

Explanation of the menu items.

[Q] Q

UIT

W

ITHOUT

S

AVING

Jump back to the “Network
Configuration” menu without
saving changes..

[R

ETURN

] Q

UIT

W

ITH

S

AVING

Jump back to the “Network
Configuration” menu and save
changes

LINDY
LINDY Rack Monitoring System
see www.lindy.com

Advertising