O

PERATION

O

PERATION

4

Rack

4.9.5

[-] Previous Feedback Input
Selection pointer to previous input.

[+] N

EXT

F

EEDBACK

I

NPUT

Selection pointer to next input.

[F] F

ILTER

Origin of the feedback.

[D] D

ELAY

T

IME

Set the delay time after the
operation of the input event f1 in s.
[H] H

OLD

T

IME

Set the hold time of f2 after the
release of f1 in s.
[P] P

ASS

C

ONDITION

Set the pass mode.
thru

pass

conditional

pass if input condi-
tion is still met

[E] E

FFECT

State how the input acts on
the OR element.
thru

switched through

off switched

off

invert

switched through

in inverted fashion

[?] H

ELP

Explanation of the menu
items.

[Q] Q

UIT

Jump back to the previous
menu.

FEEDBACK INPUTS

To realise complex filter conditi-
ons, each filter has two feedback
inputs where filter events can be
further processed.
The special feature here is the
possibility of delay (delay time),
conditional evaluation (pass
condition) and hold time.

F1: Filter 1
F2: Feedback input of filter 2.
f1: F1 output event, input event

of F2

f2: Output of the feedback input

of F2

With a pass condition = thru,
the effective hold time of f2 can
be extended by any time by sub-
sequent events of f1 (retriggering).
f2 in this case is not released
until thold after the last falling
edge of f1.

Advertising