Loctite CARTESIAN 400 User Manual

Page 57

Advertising
background image

[endWait] and [timeUp] cannot be used alone.

A period for Time Out of “waitCondTime” can be set using variable and expressions.


Example)

declear num wtime
if
ld #genIn3
then
wtime = 3000
else
wtime = 1000
endIf
waitCondTime wtime
ld #genIn2
timeUp
set #genOut2
waitStartBZ
reset #genOut2
endWait

Declare the local variable “wtime.”
If
#genIn3=ON
then
Assign 3000 to”wtime.”
if
Assign 1000 to “wtime.”

Wait for 3 seconds/1 second until the following conditions are met.
#genIn2=ON (Condition)

If the conditions are not met within 3 seconds/1 second,
Output ON signal to #genOut2,
Stand by in place until a start instruction comes.
When a start instruction comes, output OFF signal to #genOut2.

End of the command line if the conditions are not met within 3
seconds/1 second.

Features II CARTESIAN Benchtop Robot

39

Advertising
This manual is related to the following products: