Loctite CARTESIAN 400 User Manual

Page 97

Advertising
background image


Setting Wait Time for receiving data from the COM: setWTCOM
You can set Wait Time for receiving data using “inCOM” or “cmpCOM” command. If no data is
received after a specified time goes by, it will be recognized as Time out. (Turns a system flag ON.)
0.1 sec is set for the defalt wait time.



Clearing COM Receive Buffer: clrCOM
Receive buffer is a place where received data is stored. Each port has a receive buffer (8 kbyte.)
New received data will not replace the existing receive data but will be written after the existing data.
A receive buffer will be cleared by turning the power OFF or executing “clrCOM” command.



Shifting COM Receive Data: shiftCOM
A specified data byte of the receive buffer is deleted.

e.g.: 2-byte Shift

Receive Buffer

A B C D E F G H

C D E F G H

You can tell whether the data is stored in each receive buffer by its system flag.

If a receive buffer has received data, a corresponding system flag comes ON.

COM1 COM2 COM3

COM4

(TPU)

With received data

sysFiag(1)

sysFiag(6) sysFiag(11) sysFiag(16)